| Type | 3P | SD16R | SD20R | SD25R | SD32R | SD40R | SD63R | SD80R | SD80HR | SD100R | SD125R |
| 4P | |||||||||||
| Oerienkommen ferwaarmingsstroom (≤40 °C) | 16A | 20A | 25A | 32A | 40A | 63A | 80A | 100A | 100A | 125A | |
| IEC-beoardiele operasjoneel stroom Ie AC-21A/B (≤690V) | 16A/16A | 20A/20A | 25A/25A | 32A/32A | 40A/40A | 63A/63A | 80A/80A | 100A/100A | 100A/100A | 125A/125A | |
| IEC-nominale operasjonele stroom D.w.s. AC-22A/B | 415V | 16A/16A | 20A/20A | 25A/25A | 32A/32A | 40A/40A | 63A/63A | 80A/80A | 100A/100A | 100A/100A | 125A/125A |
| 500V | |||||||||||
| 690V | 32A/40A | 40A/63A | 63A/80A | 63A/80A | 80A/100A | 100A/125A | |||||
| IEC-nominale operasjonele stroom Ie AC-23A/B | 415V | 16A/16A | 20A/20A | 25A/25A | 32A/32A | 40A/40A | 63A/63A | 80A/80A | 100A/100A | 100A/100A | 125A/125A |
| 500V | 25A/25A | 63A/63A | 80A/100A | 100A/100A | |||||||
| 690V | 40A/40A | 63A/63A | 63A/63A | ||||||||
| IEC-nominale operasjonele stroom Ie DC-21B | 110VDC | 16A(1) | 20A(1) | 25A(1) | 32A(1) | 40A(1) | 63A(1) | 80A(1) | 100A(1) | 100A(1) | 125A(1) |
| 250VDC | 16A(2) | 20A(2) | 25A(2) | 32A(2) | 40A(2) | 63A(2) | 80A(2) | 100A(2) | 100A(2) | 125A(2) | |
| 400VDC | 16A(3) | 20A(3) | 25A(3) | 25A(3) | 40A(3) | 63A(3) | |||||
| IEC-beoardiele operasjonele krêft (3-fase) AC-23A/B | 415V | 7.5KW | 9KW | 11 kW | 15 kW | 18.5KW | 30 kW | 37KW | 45KW | 55 kW | |
| 500V | |||||||||||
| 690V | 11 kW | 15 kW | |||||||||
| Koartslutingbestindige stroom fan lontbeskerming (ferwachte wearde fan kA rms) | |||||||||||
| Fuseklasse | 16A | 20A | 25A | 32A | 40A | 63A | 80A | 100A | 125A | ||
| Beoardiele betingst koartslutingstroom | 50kA | 25kA | |||||||||
| Koartsluting wjerstean stroom fan stroombrekker foar beskerming, elke stroombrekker dy't binnen 0.3s kin útskeakelje | |||||||||||
| Koarte-tiid wurdearre stroom wjerstean | 2,5 kA | 3kA | 5 kA | ||||||||
| Koartslutingprestaasjes (ûnbeskerme) | |||||||||||
| Rated koarte-tiid wjerstânsstroom | 1.26kA | 1,5 kA | 2.75kA | ||||||||
| Rated koartsluting meitsjen kapasiteit | 1.8kA | 2.1kA | 3.9kA | ||||||||
| Kruisgebiet fan terminals | 1,5~16mm² | 2,5-35 mm² | 10~70mm² | ||||||||
| Nominale isolaasjespanning Ui | 800V | ||||||||||
| Nominale ympulsbehâldspanning Uimp | 8kV | ||||||||||
| Mechanyske úthâldingsfermogen | 100000 | ||||||||||
| Omjouwingstemperatuer | Yn wurking -25°C…+55°C / Opslach -40°C…+70°C | ||||||||||
| (1) Elke peal wurdt brûkt as posityf en negatyf (2) Trije poalen wurde yn searje brûkt mei positive en negative poalen, wêrfan twa poalen yn searje binne, en de oare negatyf is. (3) Fjouwer poalen wurde yn searje brûkt mei positive en negative poalen | |||||||||||