Technyske data
| IEC Electrical | | | 150 | 275 | 320 |
| Nominale AC spanning (50/60Hz) | | Uc/Un | 120V | 230V | 230V |
| Maksimum trochgeande wurkspanning (AC) | (LN) | Uc | 150V | 270V | 320V |
| (N-PE) | Uc | 255V |
| Nominale ûntlaadstroom (8/20μs) | (LN)/(N-PE) | In | 20 kA/50 kA |
| Maksimum ûntlaadstroom (8/20μs) | (LN)/(N-PE) | Imax | 50 kA/100 kA |
| Impulsútlaadstroom (10/350μs) | (LN)/(N-PE) | Iimp | 12,5 kA/50 kA |
| Spesifike enerzjy | (LN)/(N-PE) | W/R | 39 kJ/Ω / 625 kJ/Ω |
| Kosten | (LN)/(N-PE) | Q | 6,25 As/12,5 As |
| Voltage Protection Level | (LN)/(N-PE) | Up | 1,0 kV/1,5 kV | 1,5 kV/1,5 kV | 1.6kV/1.5kV |
| (N-PE) | Ifi | 100 ARMS |
| Reaksjetiid | (LN)/(N-PE) | tA | <25 ns/<100 ns |
| Back-up fuse (max) | | | 315A/250A gG |
| Koartesluting hjoeddeistige beoardieling (AC) | (LN) | ISCCR | 25 kA/50 kA |
| TOV Standert 5s | (LN) | UT | 180V | 335V | 335V |
| TOV 120 min | (LN) | UT | 230V | 440V | 440V |
| | wize | Safe Fail | Safe Fail | Safe Fail |
| TOV Standert 200ms | (N-PE) | UT | 1200V |
| UL Electrical | | | | | |
| Maksimum trochgeande wurkspanning (AC) | | MCOV | 150V/255V | 275V/255V | 320V/255V |
| Voltage Protection Rating | | VPR | 600V/1200V | 900V/1200V | 1200V/1200V |
| Nominale ûntlaadstroom (8/20μs) | | In | 20 kA/20 kA | 20 kA/20 kA | 20 kA/20 kA |
| Koartesluting hjoeddeistige beoardieling (AC) | | SCCR | 200 kA | 150 kA | 150 kA |
Normale Arbeidsomstannichheden
- -Hichte net mear as 2000m
- - Ambient luchttemperatuer:
- Normaal berik: -5ºC~+40ºC
- Wreidzje berik: -40ºC~+80ºC
- -Relative Feuchte: 30% - 90% ûnder temperatuer binnen
- - Op it plak sûnder fansels skodzjen en skokken trilling
- - Net-eksploazjegefaarmedium, net-korrosje gas en stof (ynklusyf geleidend stof)