Poalen | Ie Rating | Uc | Enerzjyferbrûk | Max Power | ||
AC-7a | AC-7b | (VAC) (50Hz) | Hald fol | Binnenhelje | ||
2P | 16A | 6A | 230 | 2.1VA | 2.1VA | 2.0W |
20A | 7A | 230 | 2.1VA | 2.1VA | 2.0W | |
25A | 9A | 230 | 2.1VA | 2.1VA | 2.0W | |
32A | 12A | 230 | 2.1VA | 2.1VA | 2.0W | |
40A | 18A | 230 | 2.3VA | 2.3VA | 2.0W | |
63A | 25A | 230 | 2.3VA | 2.3VA | 2.0W | |
4P | 16A | 6A | 230 | 2.3VA | 2.3VA | 2.0W |
20A | 7A | 230 | 2.3VA | 2.3VA | 2.0W | |
25A | 9A | 230 | 2.3VA | 2.3VA | 2.0W | |
32A | 12A | 230 | 2.3VA | 2.3VA | 2.0W | |
40A | 18A | 230 | 6.0VA | 6.0VA | 5.5W | |
63A | 25A | 230 | 6.0VA | 6.0VA | 5.5W |
Auxiliary Kontakten
De Auxiliary kontakten binne indicator contactor kontakten status switch OFF of ON
AC-12 | AC-15 | DC-13 | Rated Aktueel | ||||
CV | CA | CV | CA | CV | CA | ||
BMC7-AUC11 | 240V | 5A | 230V | 2A | DC 130V | 1A | 5A |
BMC7-AUC20 | 240V | 5A | 230V | 2A | DC 130V | 1A | 5A |
Spaasje stik
Spacers wurde brûkt om de temperatuerferheging te ferminderjen fan apparaten dy't njonken inoar monteare, it is oan te rieden om elektroanyske apparatuer te skieden
(apparaten foar temperatueroanpassing, programmeerbere timer ensfh.) Fan elektromeganyske apparatuer (ympulsrelais, kontaktors)
Technyske spesifikaasjes | |
Spaasje stik | 3mm Spacing stik |
9mm Spacing stik |
Main parameter en technyske prestaasjes
Power circuit | ||
Voltage rating (Ue) | 1P,2P | 250V AC |
3p,4p | 400V AC | |
Frekwinsje | 50/60 Hz | |
Endurance (OC) | 1.000.000 syklusen | |
Elektrysk | 100.000 syklusen | |
Maksimum oantal switching operaasje per dei | 100 | |
Isolaasjespanning (Ui) | 500V AC | |
Fersmoarging graad | 2 | |
Rated ympuls wjerstân spanning (Uimp) | 2.5kV (4kV foar 12/24/48VAC) | |
Beskermingsgraad (IEC 60529) | Allinnich apparaat | IP20 |
Apparaat yn modulêre omwâling | IP40 | |
Operating temperatuer | -5ºC~+60ºC | |
Storage temperatuer | -40ºC~+70ºC | |
Tropicalization (IEC 60068.1) | Behanneling 2 (relative vochtigheid 95% by 55ºC | |
ELSV-neilibjen (Extra Low Safety Voltage) foar 12/24/48vac ferzjes | ||
De produktkontrôle komt oerien mei de SELV (feiligens ekstra lege spanning) easken |